Sample Cleanup Columns for Mycotoxins

Romer Labs offers a wide variety of cleanup columns for mycotoxins. These range from simple one-step cleanup with MycoSep® and MultiSep® technology to immunoaffinity cleanup. These cleanup columns, some of which part of AOAC and CEN methods, ensure a fast and reliable purification of your samples.

MycoSep

MycoSep®   

Cleanup Columns

MycoSep® columns represent one-step cleanup columns containing packing materials made of adsorbent mixes specially designed for all food and feed commodities, for fast cleanup within 30 seconds. Cleanup is possible for all EU regulated mycotoxins.

For cleanup with MycoSep® systems, the column is pushed into a test tube containing the sample extract, forcing it to filter upwards. Interferences adhere to the chemical packaging and the purified extract, containing all the mycotoxins, can be collected from the top of the cleanup column.

A complete overview can be found below. Click on the item numbers for more information.

Item No.ProductSpecificityNo. of Columns
MycoSep® 
COCMY2112MycoSep® 112 AflaZonAflatoxins B1, B2, G1 & G2, Zearalenone, Zearalenol, Zearalanol25
COCMY21131,2MycoSep® 113 TrichTrichothecenes, Type A & B25
COCMY2150MycoSep® 150 ErgotErgot Alkaloids25
COCMY22241MycoSep® 224 AflaZonAflatoxins B1, B2, G1 & G2, Zearalenone, Zearalenol, Zearalanol25
COCMY2225MycoSep® 225 TrichTrichothecenes, Type A & B25
COCMY2226MycoSep® 226 AflaZon+Aflatoxins B1, B2, G1 & G2, Zearalenone, Zearalenol, Zearalanol25
COCMY22271,2MycoSep® 227 Trich+Trichothecenes, Type A & B25
COCMY22282MycoSep® 228 AflaPatAflatoxins B1, B2, G1 & G2, Patulin25
COCMY2229MycoSep® 229 OchraOchratoxin A25
COCMY2230MycoSep® 230 NivNivalenol25
COCMY2231MycoSep® 231 FumFumonisin B1, B2 & B325
COCMY2240MycoSep® 240 MonMoniliformin25

1AOAC official method
2Japanese official method

MultiSep

MultiSep®  

Cleanup Columns

MultiSep® columns represent one-step cleanup columns containing packing materials made of adsorbent mixes specially designed for all food and feed commodities, for fast cleanup within 30 seconds.

Using MultiSep® cleanup, the extract is applied on top of the column and passes through either by gravity or by applying vacuum or positive pressure. The purified extract, containing all the mycotoxins, passes through, whereas interferences adhere to the chemical packing.

A complete overview can be found below. Click on the item numbers for more information.

Item No.ProductSpecificityNo. of Columns
MultiSep® 
COCMU2211MultiSep® 211 FumFumonisin B1, B2 & B325
COCMU2216MultiSep® 216Trichothecenes, Type A & B25
COCMU2224MultiSep® 224 AflaZonAflatoxins B1, B2, G1 & G2, Zearalenone, Zearalenol, Zearalanol 25
COCMU2225MultiSep® 225 TrichTrichothecenes, Type A & B25
COCMU2226MultiSep® 226 AflaZon+Aflatoxins B1, B2, G1 & G2, Zearalenone, Zearalenol, Zearalanol 25
COCMU22271,2MultiSep® 227 Trich+Trichothecenes, Type A & B25
COCMU22282MultiSep® 228 AflaPatAflatoxins B1, B2, G1 & G2, Patulin25
COCMU2229MultiSep® 229 OchraOchratoxin A25
COCMU2230MultiSep® 230 NivNivalenol25

1AOAC official method
2Japanese Department of Agriculture approved

MycoSpin

MycoSpin®

Cleanup Columns

Romer Labs MycoSpin® 400 multi-mycotoxin two-step cleanup column in a spin format was developed to be used for most regulated mycotoxins to shorten the time-consuming cleanup process. Multiple mycotoxins can be analyzed simultaneously by LC-MS/MS.

Highly accurate LC-MS/MS results are achieved by combining the MycoSpin® 400 cleanup with Biopure™ 13C isotope labeled standards.

Click on the item number below for more information.

Item No.ProductSpecificityNo. of Columns
MycoSpin®
COCMY2400MycoSpin® 400 MultitoxinAflatoxin B1, B2, G1 & G2, Trichothecenes Type A & B, Zearalenone, Ochratoxin A, Fumonisin B1, B2 & B325
StarLine

StarLineTM

Immunoaffinity Columns

The wide range of StarLine™ immunoaffinity columns (IAC) for regulated mycotoxins is based on a specific antibody-analyte binding technology. Toxin-specific antibodies coupled to gel particles capture the mycotoxins in the sample and release them after a washing step.

StarLine™ immunoaffinity columns are designed for simple and reliable cleanup before detection of mycotoxins in a broad range of different commodities. Those IAC can be used for the purification as well as concentration of mycotoxins prior to analysis by various techniques, such as HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.

All Romer Labs IAC employ highly specific, monoclonal antibodies.

A complete overview can be found below. Click on the item numbers for more information.

Item No.SpecificityFormatNo. of Columns
AflaStar™ FIT
COIAC1001Aflatoxins B1, B2, G1 & G21 mL25
COIAC1501Aflatoxins B1, B2, G1 & G21 mL500
Item No.Quantitation RangeLimit of DetectionNo. of Tests
AflaStar™ R
COIAC1004Aflatoxins B1, B2, G1 & G23 mL25
COIAC1504Aflatoxins B1, B2, G1 & G23 mL500
Item No.Quantitation RangeLimit of DetectionNo. of Tests
AflaStar™ M1 R
COIAC1005Aflatoxin M13 mL25
Item No.Quantitation RangeLimit of DetectionNo. of Tests
OchraStar™ FIT
COIAC2001Ochratoxin A1 mL25
Item No.Quantitation RangeLimit of DetectionNo. of Tests
OchraStar™ R
COIAC2004Ochratoxin A3 mL25
Item No.Quantitation RangeLimit of DetectionNo. of Tests
FumoniStar™
COIAC3000Fumonisin B1, B2, B33 mL25
Item No.Quantitation RangeLimit of DetectionNo. of Tests
DONStar™
COIAC5000Deoxynivalenol3 mL25
Item No.Quantitation RangeLimit of DetectionNo. of Tests
ZearaStar™ R
COIAC4004Zearalenone3 mL25
Item No.Quantitation RangeLimit of DetectionNo. of Tests
T2/HT2 Star™ R
COIAC6004T2 Toxin, HT2 Toxin3 mL25
Equipment


Additional Equipment

Romer Labs also offers additional equipment. For some analyzes (eg. aflatoxins) by HPLC-FLD, a derivatization of the analytes is necessary. Romer Labs provides equipment like the Romer Derivatization Unit (RDU, photochemical) and the Romer Cell (electrochemical) for post-column derivatization.

Romer Labs Evap System can be used for rapid evaporation of common organic solvents.

Item No.Description
RDUTM
EQOLE1480Romer® Derivatization Unit
Item No.Description
Romer® Cell
EURCO1080Romer® Cell
Item No.Description
Romer Evap® System
EQOEV103012 Port, small, 115V
EQOEV103312 Port, large, 115V
EQOEV104024 Port, small, 115V
EQOEV104324 Port, large, 115V
EQOEV103112 Port, small, 230V
EQOEV103212 Port, large, 230V
EQOEV104124 Port, small, 230V
EQOEV104224 Port, large, 230V