Sample Cleanup Columns for Mycotoxins
Romer Labs offers a wide variety of cleanup columns for mycotoxins. These range from simple one-step cleanup with MycoSep® and MultiSep® technology to immunoaffinity cleanup. These cleanup columns, some of which part of AOAC and CEN methods, ensure a fast and reliable purification of your samples.
Romer Labs provides the following cleanup solutions:

MycoSep®
Cleanup Columns
MycoSep® columns represent one-step cleanup columns containing packing materials made of adsorbent mixes specially designed for all food and feed commodities, for fast cleanup within 30 seconds. Cleanup is possible for all EU regulated mycotoxins.
For cleanup with MycoSep® systems, the column is pushed into a test tube containing the sample extract, forcing it to filter upwards. Interferences adhere to the chemical packaging and the purified extract, containing all the mycotoxins, can be collected from the top of the cleanup column.
A complete overview can be found below. Click on the item numbers for more information.
Item No. | Number Of Columns | Notes |
MycoSep 150 Ergot | ||
---|---|---|
10001950 | 25 | - |
MycoSep 228 AflaPat | ||
10001955 | 25 | - |
MycoSep 229 Ochra | ||
10001956 | 25 | - |
MycoSep 240 Mon | ||
10001959 | 25 | - |
MycoSep® AflaZon | ||
10001948 | 25 | MycoSep 112 AflaZon |
10001951 | 25 | MycoSep 224 AflaZon |
10001953 | 25 | MycoSep 226 AflaZon+ |
MycoSep® Trich | ||
10001949 | 25 | MycoSep 113 Trich |
10001952 | 25 | MycoSep 225 Trich |
10001954 | 25 | MycoSep 227 Trich+ |

MultiSep®
Cleanup Columns
MultiSep® columns represent one-step cleanup columns containing packing materials made of adsorbent mixes specially designed for all food and feed commodities, for fast cleanup within 30 seconds.
Using MultiSep® cleanup, the extract is applied on top of the column and passes through either by gravity or by applying vacuum or positive pressure. The purified extract, containing all the mycotoxins, passes through, whereas interferences adhere to the chemical packing.
A complete overview can be found below. Click on the item numbers for more information.
Item No. | Number Of Columns | Notes |
MultiSep 211 Fumonisins | ||
---|---|---|
10001937 | 25 | - |
MultiSep 216 Trich | ||
10001938 | 25 | - |
MultiSep 228 AflaPat | ||
10001943 | 25 | - |
MultiSep 229 Ochra | ||
10001944 | 25 | - |
MultiSep AflaZon | ||
10001939 | 25 | MultiSep 224 AflaZon, |
10001941 | 25 | MultiSep 226 AflaZon+ |
MultiSep Trich | ||
10001940 | 25 | MultiSep 225 Trich |
10001942 | 25 | MultiSep 227 Trich+ |

MycoSpin®
Cleanup Columns
Romer Labs MycoSpin® 400 multi-mycotoxin two-step cleanup column in a spin format was developed to be used for most regulated mycotoxins to shorten the time-consuming cleanup process. Multiple mycotoxins can be analyzed simultaneously by LC-MS/MS.
Highly accurate LC-MS/MS results are achieved by combining the MycoSpin® 400 cleanup with Biopure™ 13C isotope labeled standards.
Click on the item number below for more information.
Item No. | Product | Specificity | No. of Columns |
MycoSpin® | |||
---|---|---|---|
10001961 | MycoSpin® 400 Multitoxin | Aflatoxin B1, B2, G1 & G2, Trichothecenes Type A & B, Zearalenone, Ochratoxin A, Fumonisin B1, B2 & B3 | 25 |

StarLineTM
Immunoaffinity Columns
The wide range of StarLine™ immunoaffinity columns (IAC) for regulated mycotoxins is based on a specific antibody-analyte binding technology. Toxin-specific antibodies coupled to gel particles capture the mycotoxins in the sample and release them after a washing step.
StarLine™ immunoaffinity columns are designed for simple and reliable cleanup before detection of mycotoxins in a broad range of different commodities. Those IAC can be used for the purification as well as concentration of mycotoxins prior to analysis by various techniques, such as HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.
All Romer Labs IAC employ highly specific, monoclonal antibodies.
A complete overview can be found below. Click on the item numbers for more information.
Item No. | Format | Number Of Columns | Notes |
AflaStar R M1 | |||
---|---|---|---|
10001964 | - | 25 | - |
FumoniStar Immunoaffinity columns | |||
10001971 | 3 mL of antibody gel | 25 | - |
T2/HT2 Star R Immunoaffinity columns | |||
10001977 | 3 mL of antibody gel | 25 | - |
AflaStar Immunoaffinity columns | |||
10001962 | 1 mL of antibody gel | 25 | AflaStar FIT |
10001963 | 3 mL of antibody gel | 25 | AflaStar R |
10001965 | 1 mL of antibody gel | 500 | AflaStar FIT |
10001966 | 3 mL of antibody gel | 500 | AflaStar R |
DonStar Immunoaffinity columns | |||
10001974 | 3 mL of antibody gel | 25 | DONStar |
OchraStar Immunoaffinity columns | |||
10001968 | 3 mL of antibody gel | - | OchraStar |
10001970 | 3 mL of antibody gel | - | OchraStar R |
ZearaStar Immunoaffinity columns | |||
10001973 | 3 mL of antibody gel | - | ZearaStar R |
FolStar Immunoaffinity Columns | |||
10005406 | 3 mL of antibody gel | 25 | - |
Biotin Star Immunoaffinity Columns | |||
10005408 | - | 25 | - |
B12 Star Immunoaffinity Columns | |||
10005409 | - | 25 | - |
AflaOchraStarTM IAC | |||
10006167 | - | 25 | - |
PBS Tablets for IAC (1L PBS BUFFER) | |||
10006973 | - | - | - |

StarLine™
Immunoaffinity Columns
MultiStar™ immunoaffinity columns belong to the StarLine™ portfolio of immunoaffinity column (IAC). These columns are designed for the reliable clean-up of samples to simplify the detection of several mycotoxins at once in a broad range of different commodities.
MultiStar™ immunoaffinity columns combine the high purification potential of an immunoaffinity column with the convenience and power of multi-mycotoxin analysis, allowing for all regulated mycotoxins to be determined simultaneously in a single run.
Item no. | Analytes | No. of columns |
MultiStar™ - Immunoaffinity Column | ||
---|---|---|
10005407 | Aflatoxins, OTA, ZON, DON, FUM, T2 and HT2 | 25 |

Additional Equipment
Romer Labs also offers additional equipment. For some analyzes (eg. aflatoxins) by HPLC-FLD, a derivatization of the analytes is necessary. Romer Labs provides equipment like the Romer Derivatization Unit (RDU, photochemical) and the Romer Cell (electrochemical) for post-column derivatization.
Romer Labs Evap System can be used for rapid evaporation of common organic solvents.
Item No. | Description |
Romer® Cell | |
---|---|
10002778 | Romer® Cell |
Item No. | Description |
Romer Evap® System | |
---|---|
10002546 | 12 Port, small, 115V |
10002549 | 12 Port, large, 115V |
10002550 | 24 Port, small, 115V |
10002553 | 24 Port, large, 115V |
10002547 | 12 Port, small, 230V |
10002548 | 12 Port, large, 230V |
10002551 | 24 Port, small, 230V |
10002552 | 24 Port, large, 230V |