Sample Cleanup Columns for Mycotoxins

Romer Labs offers a wide variety of cleanup columns for mycotoxins. These range from simple one-step cleanup with MycoSep® and MultiSep® technology to immunoaffinity cleanup. These cleanup columns, some of which part of AOAC and CEN methods, ensure a fast and reliable purification of your samples.

MycoSep

MycoSep®   

Cleanup Columns

MycoSep® columns represent one-step cleanup columns containing packing materials made of adsorbent mixes specially designed for all food and feed commodities, for fast cleanup within 30 seconds. Cleanup is possible for all EU regulated mycotoxins.

For cleanup with MycoSep® systems, the column is pushed into a test tube containing the sample extract, forcing it to filter upwards. Interferences adhere to the chemical packaging and the purified extract, containing all the mycotoxins, can be collected from the top of the cleanup column.

A complete overview can be found below. Click on the item numbers for more information.

Item No. Number Of Columns Notes
MycoSep 112 AflaZon
10001948 25 MycoSep 112 AflaZon
MycoSep 113 Trich
10001949 25 MycoSep 113 Trich
MycoSep 150 Ergot
10001950 25 -
MycoSep 224 AflaZon
10001951 25 MycoSep 224 AflaZon
MycoSep 226 AflaZon+
10001953 25 MycoSep 226 AflaZon+
MycoSep 227 Trich+
10001954 25 MycoSep 227 Trich+
MycoSep 228 AflaPat
10001955 25 -
MycoSep 229 Ochra
10001956 25 -
MycoSep 230 Niv
10001957 25 -
MycoSep 231 Fum
10001958 25 -
MycoSep 240 Mon
10001959 25 -
MycoSep® AflaZon
10001948 25 MycoSep 112 AflaZon
10001951 25 MycoSep 224 AflaZon
10001953 25 MycoSep 226 AflaZon+
MycoSep® Trich
10001949 25 MycoSep 113 Trich
10001952 25 MycoSep 225 Trich
10001954 25 MycoSep 227 Trich+
MultiSep

MultiSep®  

Cleanup Columns

MultiSep® columns represent one-step cleanup columns containing packing materials made of adsorbent mixes specially designed for all food and feed commodities, for fast cleanup within 30 seconds.

Using MultiSep® cleanup, the extract is applied on top of the column and passes through either by gravity or by applying vacuum or positive pressure. The purified extract, containing all the mycotoxins, passes through, whereas interferences adhere to the chemical packing.

A complete overview can be found below. Click on the item numbers for more information.

Item No. Number Of Columns Notes
MultiSep 211 Fumonisins
10001937 25 -
MultiSep 216 Trichothecenes
10001938 25 -
MultiSep 228 AflaPat
10001943 25 -
MultiSep 229 Ochra
10001944 25 -
MultiSep 230 Niv
10001945 25 -
MultiSep AflaZon
10001939 25 MultiSep 224 AflaZon,
10001941 25 MultiSep 226 AflaZon+
MultiSep Trich
10001940 25 MultiSep 225 Trich
10001942 25 MultiSep 227 Trich+
MycoSpin

MycoSpin®

Cleanup Columns

Romer Labs MycoSpin® 400 multi-mycotoxin two-step cleanup column in a spin format was developed to be used for most regulated mycotoxins to shorten the time-consuming cleanup process. Multiple mycotoxins can be analyzed simultaneously by LC-MS/MS.

Highly accurate LC-MS/MS results are achieved by combining the MycoSpin® 400 cleanup with Biopure™ 13C isotope labeled standards.

Click on the item number below for more information.

Item No. Product Specificity No. of Columns
MycoSpin®
10001961 MycoSpin® 400 Multitoxin Aflatoxin B1, B2, G1 & G2, Trichothecenes Type A & B, Zearalenone, Ochratoxin A, Fumonisin B1, B2 & B3 25
StarLine

StarLineTM

Immunoaffinity Columns

The wide range of StarLine™ immunoaffinity columns (IAC) for regulated mycotoxins is based on a specific antibody-analyte binding technology. Toxin-specific antibodies coupled to gel particles capture the mycotoxins in the sample and release them after a washing step.

StarLine™ immunoaffinity columns are designed for simple and reliable cleanup before detection of mycotoxins in a broad range of different commodities. Those IAC can be used for the purification as well as concentration of mycotoxins prior to analysis by various techniques, such as HPLC, GC-MS, LC-MS, ELISA or direct fluorometry.

All Romer Labs IAC employ highly specific, monoclonal antibodies.

A complete overview can be found below. Click on the item numbers for more information.

Item No. Format Number Of Columns Notes
AflaStar R M1
10001964 - 25 -
FumoniStar Immunoaffinity columns
10001971 3 mL of antibody gel 25 -
T2/HT2 Star R Immunoaffinity columns
10001977 3 mL of antibody gel 25 -
PBS TABLETS FOR IAC (TO PRODUCE 1L PBS BUFFER)
10002279 - - -
AflaStar Immunoaffinity columns
10001962 1 mL of antibody gel 25 AflaStar FIT
10001963 3 mL of antibody gel 25 AflaStar R
10001965 1 mL of antibody gel 500 AflaStar FIT
10001966 3 mL of antibody gel 500 AflaStar R
DonStar Immunoaffinity columns
10001974 3 mL of antibody gel 25 DONStar
10001975 3 mL of antibody gel 25 DONStar R
OchraStar Immunoaffinity columns
10001970 3 mL of antibody gel - OchraStar R
ZearaStar Immunoaffinity columns
10001973 3 mL of antibody gel - ZearaStar R
Equipment


Additional Equipment

Romer Labs also offers additional equipment. For some analyzes (eg. aflatoxins) by HPLC-FLD, a derivatization of the analytes is necessary. Romer Labs provides equipment like the Romer Derivatization Unit (RDU, photochemical) and the Romer Cell (electrochemical) for post-column derivatization.

Romer Labs Evap System can be used for rapid evaporation of common organic solvents.

Item No. Description
RDUTM
10002724 Romer® Derivatization Unit
Item No. Description
Romer® Cell
10002778 Romer® Cell
Item No. Description
Romer Evap® System
10002546 12 Port, small, 115V
10002549 12 Port, large, 115V
10002550 24 Port, small, 115V
10002553 24 Port, large, 115V
10002547 12 Port, small, 230V
10002548 12 Port, large, 230V
10002551 24 Port, small, 230V
10002552 24 Port, large, 230V

Looking for more information?  

Contact us now!Knowledge CenterOnline Shop